Young Ultrasonic Anemometer Voltage and Serial Output Mo Manuale Utente

Navigare online o scaricare Manuale Utente per Sensori Young Ultrasonic Anemometer Voltage and Serial Output Mo. Young Ultrasonic Anemometer Voltage and Serial Output Model 85000 User Manual Manuale Utente

  • Scaricare
  • Aggiungi ai miei manuali
  • Stampa
  • Pagina
    / 16
  • Indice
  • SEGNALIBRI
  • Valutato. / 5. Basato su recensioni clienti
Vedere la pagina 0
METEOROLOGICAL INSTRUMENTS
INSTRUCTIONS
R.M. YOUNG COMPANY 2801 AERO PARK DRIVE, TRAVERSE CITY, MICHIGAN 49686, USA
TEL: (231) 946-3980 FAX: (231) 946-4772 WEB: www.youngusa.com
PN: 85000-90
REV: J110410
ULTRASONIC ANEMOMETER
MODEL 85000
Vedere la pagina 0
1 2 3 4 5 6 ... 15 16

Sommario

Pagina 1 - METEOROLOGICAL INSTRUMENTS

METEOROLOGICAL INSTRUMENTSINSTRUCTIONSR.M. YOUNG COMPANY 2801 AERO PARK DRIVE, TRAVERSE CITY, MICHIGAN 49686, USATEL: (231) 946-3980 FAX: (23

Pagina 2 - OPERATING INSTRUCTIONS

Page 785000-908.0 WARRANTYThis product is warranted to be free of defects in materials and construction for a period of 12 months from da

Pagina 3

Page 885000-90APPENDIX A: WIRING CONNECTIONS

Pagina 4 - MODEL 85000

Page 985000-90APPENDIX A: WIRING CONNECTIONS

Pagina 5 - 5.0 OPERATION

Page 1085000-90APPENDIX A: WIRING CONNECTIONS

Pagina 6

Page 1185000-90APPENDIX A: WIRING CONNECTIONS

Pagina 7 - PARAMETERS

Page 1285000-90APPENDIX A: WIRING CONNECTIONS

Pagina 8 - SET09nn Damping factor

Page 1385000-90APPENDIX B: SENSOR ORIENTATION AND DIMENSIONSTOP VIEWNORTH347 [13.7]FRONT VIEWORIENTATION RING0°90°180°270°(WIND SPEED, WIND DIRECTI

Pagina 9 - 7.0 EXAMPLE SETTINGS

85000-90(J) ContentsSECTION DESCRIPTION PAGE1.0 SPECIFICATIONS 12.0 INTRODUCTION

Pagina 11 - 85000-90

Page 185000-90MODEL 85000ULTRASONIC ANEMOMETER1.0 SPECIFICATIONSWIND SPEEDRange: 0-70 m/s (156 mph)Resolution: 0.1 m/sAccuracy: 0 to 30 m/s, ±2%

Pagina 12

Page 285000-90 IMPORTANT: The Wind Tracker input option must be set to "INP 09". See the Wind Tracker manual for set-ting this option.3.2

Pagina 13 - Page 10

Page 385000-905.3.2 ASCIIASCII output provides continuous wind measurement data in text format. Between each measurement cycle, the sensor goes into

Pagina 14 - Page 11

Page 485000-90 aD0! a+www.w+ddd<CRC><CR><LF> a±uu.uu±vv.vv<CRC><CR><LF> where: a = Sensor address ddd =

Pagina 15 - Page 12

Page 585000-90Although new parameter values are stored immediately when the command is issued, they do not take effect until the sensor enters OPE

Pagina 16 - CARTESIAN

Page 685000-90The default value is 4. When set to 00, no damping is applied. Higher damping factors slow the rate at which the sensor ind

Commenti su questo manuale

Nessun commento