Young Ultrasonic Anemometer Voltage and Serial Output Mo Manuale Utente

Navigare online o scaricare Manuale Utente per Sensori Young Ultrasonic Anemometer Voltage and Serial Output Mo. Young Ultrasonic Anemometer Voltage and Serial Output Model 81000 User Manual Manuale Utente

  • Scaricare
  • Aggiungi ai miei manuali
  • Stampa
  • Pagina
    / 11
  • Indice
  • SEGNALIBRI
  • Valutato. / 5. Basato su recensioni clienti
Vedere la pagina 0


R.M. YOUNG COMPANY 2801 AERO PARK DRIVE, TRAVERSE CITY, MICHIGAN 49686, USA
TEL: (231) 946-3980 FAX: (231) 946-4772 WEB: www.youngusa.com
PN: 81000-90
REV: I102210
ULTRASONIC ANEMOMETER
MODEL 81000
Vedere la pagina 0
1 2 3 4 5 6 ... 10 11

Sommario

Pagina 1 - 

R.M. YOUNG COMPANY 2801 AERO PARK DRIVE, TRAVERSE CITY, MICHIGAN 49686, USATEL: (231) 946-3980 FAX: (23

Pagina 2 - MODEL 81000

Page 981000-90APPENDIX A: WIRING CONNECTIONS

Pagina 3 - 6.0 SETUP

Page 1081000-90APPENDIX B: SENSOR ORIENTATION AND DIMENSIONSNORTHTOP VIEW160 [6.3]207 [8.1]568 [22.4]MOUNTINGDEPTH114 [4.5]ORIENTATION RINGSIDE VIEW(

Pagina 4 - 6.7 SERIAL OUTPUT FORMAT

Page 181000-90MODEL 81000ULTRASONIC ANEMOMETER1.0 SPECIFICATION SUMMARYWIND SPEED Range: 0 to 40 m/s (0 to 90 mph)Resolution: 0.01 m/sThreshold: 0

Pagina 5 - 6.9 UNITS

Page 281000-903. Apply power to the 81000 sensor. There will be a 4 second delay for initialization then the unit will begin to output data at four t

Pagina 6 - 7.0 APPLICATION NOTES

Page 381000-90 BAUD: 38400 ---------------------- A) 1200 B) 2400 C) 4800 D) 9600 E) 19200 F) 38400 X) EXIT TO MAIN MENU FOR RS-48

Pagina 7 - 9.0 CE COMPLIANCE

Page 481000-90CHKSUM calculates the bitwise exclusive-or of all characters in the output string starting with the  rst character and ending with the

Pagina 8

Page 581000-90 m/s 0.01 C° 0.01 mph 0.1 F° 0.01 km/h 0.1 C° 0.01 knots 0.1 F° 0.01 UNITS 2 ------------------- 1) cm/s 2) m/s 3) mp

Pagina 9

Page 681000-90needed and, when operated in polled mode, the connections may be bussed.Long custom output strings at high output rates and low baud rat

Pagina 10 - 81000-90

Page 781000-90APPENDIX A: WIRING CONNECTIONS

Pagina 11 - CARTESIAN

Page 881000-90APPENDIX A: WIRING CONNECTIONS